Beijing Airport Instrument Co.,Ltd
   +86-15530321818

Home > PTFE Liner P10 Variable area float flow meter

  • PTFE Liner P10 Variable area float flow meter
PTFE Liner P10 Variable area float flow meter

PTFE Liner P10 Variable area float flow meter

 
PTFE Liner P10 Variable area float flow meter
Feature
1:All metal construction, strong and stable
2:Short stroke, compact structure. 
3:Low pressure loss design. 
4:New style magnetic coupling structure ensures that the signal transmission is more stable. 
5:Magnetic filter can be added as customer requirements
6:Thermal insulation or tracing heat jacket.
7:Used in the gas and liquid measurement in all industries. The measurment parts can adopt different materials to be suitable for different medias. 
8:Suitable for harsh environment and seriously corrosion media. Having good heat resistance and pressure resistance. 
9:Intelligent dual-line LCD display, on site instant/ umulative flow display and back light as options. 
10:Two-wire system, battery, alternating current can be choosed to supply the power.
           
Type  R56  
Medium Liquids, gases, vapors  
Flow Range Water :20℃ (10-300000)L/h ,Special orderon request:  
Air :0.1013MPa, 20℃ (0.7-3000)Nm3/h, Special order on request:  
The turn-down ratio 10:01  
Accuracy class Mechanical indicator 1.0, 1.5, 2.0, 2.5  
Mechanical indicator with LCDbattery powered, service life: 2 years 1.0, 1.5, 2.0, 2.5  
Mechanical indicator with two-wire signal output (4-20)mA/hartcommunication protocol 1.0, 1.5, 2.0, 2.5  
Medium temperature Machinery indicator with LCDbattery powered, service life: 2 years -80℃~+300℃(PTFE:0~80℃)  
High temperature 400℃  
Mechanical indicatorbattery powered, service life: 2 years -40℃~+120℃(PTFE:0~80℃)  
High temperature 400℃  
Mechanical indicator with two-wire signal output (4-20)mA/hartcommunication protocol -40℃~+120℃(PTFE:0~80℃)  
Hightemperature400℃  
Ambient temperature Mechanical indicator -40℃~+120℃  
Mechanical indicator with LCDbattery powered, service life: 2 years -20℃~+60℃  
Mechanical indicator with two-wire signal output (4-20)mA/hartcommunication -20℃~+60℃  
Viscosity of fluid DN15: F15.00~F15.03η<5 mPa.s, F15.04~15.30 η<30 mPa.s; DN25:η<250 mPa.s; DN50~250: η<300 mPa.s  
Nominal pressure DN15~DN50 4.0MPaMax DN15: 42MPa, DN25: 42MPa, DN50: 32MPa  
DN80~DN250 1.6MPaMax DN80: 10MPa, DN100: 6.4MPa, DN125: 4.0MPa  
DN150: 4.0MPa, DN200: 2.5MPa, DN250: 2.5Mpa  
Process connection Flange connection, Standard:DIN2501, ANSI, JISselectChinese standard freely, priority select DIN  
Hygieneclamp, screw jointare selected in the order  
Electrical connection M20×1.5     1/2"G     1/2"NPT      3/4"G     3/4"NPT  
Installation Vertical mountingbottom in up out and up in bottom out, Horizontal mountingleft in rightout and right in left out  
bottom in side out, side in side out  
Straight unimpeded inlet run ≥5D  
Straight unimpeded outlet run ≥250mm  
Degree of protection  IP67(Others need specify in the order)  
Exmarking EExia II CT5  
EEx d II CT6  
Exelectricaldata Ui=28V     Ii=93mA     Pi= 0.65W    Ci≤ 5nF     Li =0mH  
Safety barrier data Uo≤ 28V   Io≤ 93mA   Po≤ 0.65W   Co≥ Ci+Cc  Lo≥ Li+Lc  
Carried Standard JB/T  6844-93  